  2 electromagnetic coupling rfid system v600 electromagnetic coupling rfid system v600 non-contact data co mmunications system ? superior environmental resistance.  heat-resistant type available (150 c max.).  high memory capacity of 8 kbytes for built-in-battery data carriers and 254 bytes for battery-less data carriers.  built-in-battery data carriers have a battery life detecting function.  data of battery-less data carriers can be overwritten 300,000 times at normal temperatures.  thin, compact, and low-cost data carriers are available.  transmission distance of 100 mm max. ordering information data carriers item specifications/design/memory capacity model built-in-battery dcs rectangular compact 65 40 15 mm 8 kbytes v600-d8kr12 thin rectangular 86 54 10.3 mm v600-d8kr13 intermediate-range rectangular 86 54 20 mm v600-d8kr04 replaceable-battery dcs compact 65 40 5 mm 2 kbytes v600-d2kr16 battery-less dcs ultrathin card-type 86 54 1.5 mm 254 bytes v600-d23p71 thin half-size card-type 50 34 1.5 mm v600-d23p72 rectangular 34 34 3.5 mm v600-d23p66n rectangular package with pfa 95 36.5 6.5 mm v600-d23p66sp rectangular compact 32 24 6 mm v600-d23p61 round super-compact 8 dia. 5 mm v600-d23p53 round compact 12 dia. 6 mm v600-d23p54 round super-compact 8 dia. 5 mm v600-d23p55
electromagnetic coupling rfid system v600 3 r/w heads id controllers item specifications/design model rectangular type dimensions: 100 100 30 mm 0.5-m cable v600-h07 (0.5 m) 2-m cable v600-h07 (2 m) 5-m cable v600-h07 (5 m) 10-m cable v600-h07 (10 m) dimensions: 53 40 23 mm 0.5-m cable v600-h11 (0.5 m) 0.5-m cable v600-h11-r (0.5 m) 2-m cable v600-h11 (2 m) 5-m cable v600-h11 (5 m) 10-m cable v600-h11 (10 m) cylinder type dimensions: 22 dia. 80 mm 0.5-m cable v600-h51 (0.5 m) 2-m cable v600-h51 (2 m) 5-m cable v600-h51 (5 m) 10-m cable v600-h51 (10 m) dimensions: 22 dia. 85 mm 0.5-m cable v600-h52 (0.5 m) 2-m cable v600-h52 (2 m) 5-m cable v600-h52 (5 m) 10-m cable v600-h52 (10 m) separate-amplifier type amplifier section 73.8 22.6 36.5 mm, with 2-m cable v600-ha51 (2 m) 73.8 22.6 36.5 mm, with 5-m cable v600-ha51 (5 m) 73.8 22.6 36.5 mm, with 10-m cable v600-ha51 (10 m) sensor section 12 dia. 35 mm deep, with 2-m cable v600-hs51 30.5 18 10 mm, with a 2-m cable v600-hs61 item specifications/design model ac power supply 100 to 240 vac, 50/60 hz two r/w head connectors 200 100 100 mm rs-232c host interface v600-ca1a-v2 rs-422 host interface v600-ca2a-v2 parallel pnp host interface v600-ca8a-v2 parallel npn host interface v600-ca9a-v2 dc power supply 24 vdc r/w head connectors 115 68 80 mm rs-232c host interface v600-cd1d-v3 24-vdc, 5-vdc 2-system input r/w head connectors board type v600-cm1d handheld controller a battery charger, ni-cd battery pack, battery case, and carrying belt are included. v600-cb-us-s ac power supply 100 to 240 vac, 50/60 hz relay contact output type idsc-c1dr-a 150 to 240 vac, 50/60 hz transistor output type idsc-c1dt-a handheld reader/writer rs-232c host in terface; use v600-a20 power pack. v600-ch1d
4 electromagnetic coupling rfid system v600 accessories (order separately) rs-232c cables (order separately) connectors for id controllers (one set per unit) item specifications/design model extension cable for r/w heads standard cable non-water-resistant connectors 3-m cable v600-a45 5-m cable v600-a44 10-m cable v600-a40 20-m cable v600-a41 30-m cable v600-a42 robotic cable non-water-resistant connectors 3-m cable v600-a56 5-m cable v600-a55 10-m cable v600-a50 20-m cable v600-a51 30-m cable v600-a52 holder for the v600-d2kr16 *mount with m3 flat counters unk head screws (at least two). v600-a81 for the v600-d23p71/d23p72 ultrasonic deposition can be us ed on the plastic container. v600-a84 attachment for the v600-d23p66n v600-a86 lithium battery for the v600-d2kr16 commercially available cr2016 battery (includes replacement battery cover seal, and cover) v600-a82 (5 in each set) power pack for the rfid ch1d reader/writer v600-a20 monitor unit special unit for the v600-ca @ a- @ controller v600-p01 cable compatible id controllers model 2-m cable xw2z-200p 5-m cable XW2Z-500P 2-m cable xw2z-200s 5-m cable xw2z-500s v600-ca1a-v2 v600-cd1d-v3 v600-cm1d connector compatible id controllers model connector plug xm2a-0901 connector hood xm2s-0911 connector plug xm2a-2501 connector hood xm2s-2511 connector plug mr-50f (honda tsushin kogyo) connector hood mr-50l (honda tsushin kogyo) v600-ca2a-v2 v600-cd1d-v3 v600-cm1d v600-ca1a-v2 v600-ca8a-v2 v600-ca9a-v2
electromagnetic coupling rfid system v600 5 specifications battery-less data carriers note: the 150 c heat resistance was confirmed by leaving the unit at 150 c for 1,000 continuous hours, and by a thermal shock test consisting of 1,000 -10 c/150 c cycles of 30 min each. no defect was found among the 22 test samples. description ultra-thin card-type ultra-thin half-size card-type rectangular compact chemical- resistant rectangular compact round super- compact round compact round super- compact item model v600- d23p71 v600- d23p72 v600- d23p66n v600- d23p66sp v600- d23p61 v600- d23p53 v600- d23p54 v600- d23p55 memory capacity 254 bytes memory type eeprom (non-volatile memory) transmission distance refer to ?t ransmission distance spec ifications for battery-less dcs? on page 12. data retention time (after writing data) 10 years 10 years ( ? 40 to 110 c) 1 year ( ? 40 to 150 c) 10 years 10 years ( ? 40 to 110 c) 1 year ( ? 40 to 150 c) number of overwrites (per address) (refer to separate item for ambient temperature) up to 0 c 800,000 times up to 25 c 400,000 times up to 60 c 300,000 times up to 85 c 100,000 times transmission error detection 16-bit crc in bot h directions (crc: cyclic redundancy check) ambient temperature for data storage ? 20 to 110 c ?4 0 to 150 c (see note.) ? 40 to 110 c ? 40 to 85 c ?4 0 to 150 c (see note.) for reading/ writing ? 10 to 70 c ? 20 to 85 c ? 20 to 70 c ? 25 to 70 c ? 25 to 85 c storage temperature ? 20 to 110 c ?4 0 to 150 c (see note.) ? 40 to 110 c ? 40 to 85 c ?4 0 to 150 c (see note.) ambient humidity operating: 35% to 95% degree of protection iec 60529: ip67 iec 60529: ip68 iec 60529: ip67 iec 60529: ip67 iec 60529: ip67 vibration resistance (destruction) 10 to 2,000 hz, 3.0-mm double amplitude, 300 m/s 2 acceleration for 30 min each in 3 directions (90 min total) 10 to 2,000 hz, 1.5-mm double ampli- tude, 150 m/ s 2 accelera- tion 10 times each in 3 di- rections (15 min) 10 to 2,000 hz, 3.0-mm double amplitude, 300 m/s 2 acceleration for 30 min each in 3 directions (90 min total) 10 to 2,000 hz, 1.5-mm double amplitude, 150 m/s 2 acceleration 10 times each in 3 directions (15 min) shock resistance (destruction) 1,000 m/s 2 3 times each in 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times to- tal) 1,000 m/s 2 3 times each in 3 directions (18 times total) 500 m/s 2 3 times each in 3 directions (18 times total) weight approx. 15 g approx. 5 g approx 6.5 g approx. 19 g approx. 5.8 g approx. 0.4 g approx. 1.0 g approx. 0.6 g
6 electromagnetic coupling rfid system v600 built-in-battery data carriers note: 1. a low battery detection function is built-in. 2. the battery life is applicable for batteries used at a temperature of 25 c. for details on the relationship between temperature and battery life, refer to ?temperature and battery life,? in this data s heet, found just before the ?precautions? section. the cr2016 is p rovided as the replacement battery (see ?accessories? in the ordering information of this data sheet). the data carrier is dustproof when the provided battery replacement cover seal is used. description rectangular compact rectangular thin rectangular intermediate range rectangular compact with replaceable battery item model v600-d8kr12 v600-d8kr13 v600-d8kr04 v600-d2kr16 memory capacity 8 kbytes 2 kbytes memory type sram (volatile memory) transmission distance refer to ?tra nsmission distance spec ifications for built-in dcs? found in the specifications section of this data sheet. battery life (see note 1.) refer to ?battery life? found in the specificat ions section of this data sheet. 2 years (at 25 c) (see note 2.) number of reads/writes unlimited unlimited (does not affect battery life) transmission error detection 16-bit crc in bot h directions (crc: cyclic redundancy check) ambient temperature for data storage ? 40 to 70 c ? 15 to 70 c for reading/ writing ? 25 to 70 c 0 to 50 c storage temperature ? 40 to 70 c ? 15 to 70 c ambient humidity 35% to 95% 35% to 85% storage humidity 35% to 95% degree of protection iec 60529: ip67 iec 60529: ip50 (dustproof) (see note 3.) vibration resistance (destruction) 10 to 500 hz, 1.0-mm single amplitude, 150 m/s 2 acceleration for 11 min each in x, y, and z directions 10 to 150 hz, 0.75-mm sin- gle amplitude, 100-m/s 2 ac- celeration for 30 min each in x, y, and z directions shock resistance (destruction) 1,000 m/s 2 3 times each in x, y, and z directions (18 times total) 300 m/s 2 3 times each in x, y, and z directions (18 times total) weight approx. 70 g approx. 160 g approx. 15 g
electromagnetic coupling rfid system v600 7 read/write (r/w) heads (w ith built-in amplifier) note: 1. extension cables are also available. the maximum cable length is 30.5 m for the v600-h07 and 50.5 m for the v600-h11/h51/h52. 2. the connectors are not water-resistant. model v600-h07 v600-h11/h11-r v600-h51 v600-h52 item oscillation frequency 530 khz ambient temperature ? 25 to 70 c ? 10 to 60 c storage temperature ? 40 to 85 c ? 25 to 75 c ambient humidity 35% to 95% storage humidity 35% to 95% insulation resistance 50 m ? (at 500 vdc) between cable terminals and case dielectric strength 1,000 vac, 50/60 hz for 1 min betw een cable terminals and case (leakage current: 1 ma max.) degree of protection iec 60529: ip67 vibration resistance (destruction) 10 to 500 hz, 1.0-mm single amplitude, 150 m/s 2 acceleration with 3 sweeps of 11 min each in x, y, and z directions shock resistance destruction: 500 m/s 2 3 times each in x, y, and z directions (18 times total) cable length (see note 1.) standard lengths of 0.5 m, 2 m, 5 m, and 10 m. wireless transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) indicators power: green; transmission: orange weight approx. 1 kg (with 10-m cable) approx. 650 g (with 10-m cable)
8 electromagnetic coupling rfid system v600 r/w heads (with separate amplifier) note: 1. extension cables are also available. the maximum cable length is 50 m for the v600-ha51. extension cables are not available for the v600-hs51/hs61. 2. the connectors are not water-resistant. sensor section amplifier section item model v600-hs51 v600-hs61 v600-ha51 oscillation frequency 530 khz --- ambient temperature ? 10 to 60 c storage temperature ? 25 to 75 c ambient humidity 35% to 95% insulation resistance 50 m ? (at 500 vdc) between cable terminals and case dielectric strength 1,000 vac 50/60 hz for 1 min between cable terminals and case (leakage current: 1 ma max.) degree of protection iec 60529: ip67 iec 60529: ip66 vibration resistance (destruction) 10 to 2,000 hz, 1.5-mm single amplitude, 300 m/s 2 accel- eration with 2 sweeps of 15 min each in 3 directions installed in panel 10 to 2,000 hz, 1.5-mm single am- plitude, 300-m/s 2 acceleration with 2 sweeps of 11 min each in 3 direc- tions din track installa- tion 10 to 500 hz, 1.0-mm single ampli- tude, 150-m/s 2 acceleration with 3 sweeps of 11 min each in 3 direc- tions shock resistance (destruction) 1,000 m/s 2 3 times each in 3 directi ons (18 times total) 500 m/s 2 3 times each in 3 directions (18 times total) cable length sensor to amplifier 2 m (fixed) --- amplifier to controller --- standard lengths of 2 m, 5 m, and 10 m (see note 1.) wireless transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) indicators --- power: green; transmission: orange weight approx. 70 g (with 2-m cable) approx. 650 g (with 10-m cable)
electromagnetic coupling rfid system v600 9 id controllers monitor unit v600-p01 (for use with v600-ca @ a controllers) the monitor unit is a monitoring device that can be mounted to an id controller. it can be used to test communications between the r/w head and data carrier when the rfid system is started up, check the data in data carriers, and read error information or statistical error information. the specifications conform to those of the id controller, except the operating temperature range is 0 c to 40 c. series v600 series (electromagnetic rfid system) model item v600-ca1a-v2 v600-ca2a-v2 v600-ca8a-v2 v600-ca9a-v2 v600-cd1d-v3 v600-cm1d host interface rs-232c rs-422a (maximum of 16 units can be connected) parallel pnp output parallel npn output rs-232c possible number of r/w heads 2 1 power supply voltage 100 to 240 vac, 50/60 hz 24 vdc 24 vdc, 5 vdc acceptable power supply voltage 85 to 264 vac 20.4 to 26.4 vdc 20.4 to 26.4 vdc 4.5 to 5.5 vdc power consumption 35 va max. 7.2 w max. 24 vdc: 7.2 w max. 5 vdc: 1.5 w max. insulation resistance 50 m ? min. (at 500 vdc) between power terminals and case, between i/o terminals and case, or between the power supply terminals an d i/o terminals dielectric strength 1,500 vac, 50/60 hz for 1 min between the points listed above; leakage current: 10 ma max. 1,000 vac, 50/60 hz for 1 min between the points listed above; leakage current: 10 ma max. noise immunity 1,500-v (p-p) pulses of 100-ns to 1- s pulse width with a 1-ns rise time vibration resistance destruction 10 to 150 hz, 0.3-mm double amplitude for 32 min each in x, y, and z directions malfunction 10 to 150 hz, 0.2-mm double amplitude fo r 32 min each in x, y, and z directions shock resistance destruction: 200 m/s 2 3 times each in x, y, and z directions (18 times total) ambient temperature ? 10 to 55 c 0 to 50 c ambient humidity 35% to 85% (with no condensation) operating conditions no corrosive gases storage temperature ? 25 to 65 c ? 15 to 70 c memory back-up a capacitor backs up the most recent error data and statistical error data for up to 20 days (at 25 c) after a power interruption. memory backup is not available. error details, however, can be read from the personal computer when the power is turned on. diagnostic functions checks for cpu errors, memory errors, power interruptions, and transmission errors ground ground to 100 ? or less. degree of protection iec 60529: ip30 (panel mounted) weight approx. 890 g approx. 930 g approx. 960 g approx 360 g approx. 180 g
10 electromagnetic coupling rfid system v600 handheld id controllers note: the continuous operating time is for new, fu lly charged nickel cadmium ba tteries or new alkaline batte ries used at room tempera ture. over- seas specifications (w ith ul-listed battery c harger) also available. v600-cb-us-s configuration handheld v600-ch1d wand note: 1. this figure is for idling or stand-by. the rush current must be 250 ma max. 2. this does not include the connector section. the main unit is not resistant to chemicals or oils. model v600-cb-us-s item power supply built-in nickel-cadmium batteries (6 v dc) or 9-v alkaline batteries (9 vdc) (see note.) power consumption 700 ma max. continuous operating time (see note.) 3 hrs min. when using the built-in nickel-cadmium batteries; 1.5 hrs min. when using the alkaline batteries automatic power-saver the power is turned off automatically if a key input or response is not received in 10 min. automatic command cancellation a command will be cancelled automatical ly if a response is not received from a data carrier within 2 min. low battery indicator this display appears when the battery voltage falls below the minimum voltage required for operation. user memory 32 kbytes (data will be retained for at least 24 hrs after batteries are removed.) vibration resistance destruction: 10 to 150 hz, 0.3-mm doub le amplitude for 32 min each in x, y, and z directions shock resistance destruction: 200 m/s 2 3 times each in x, y, and z directions (18 times total) ambient temperature 0 to 45 c ambient humidity 35% to 85% (with no condensation) operating conditions no corrosive gases storage temperature ? 25 to 60 c (excluding the battery pack) degree of protection iec 60529: ip30 weight 680 g max. (including the battery pack) item description model handheld id controller controller v600-cb-us battery charger accessory v600-a14 battery case accessory (for alkaline batteries) v600-a11 ni-cd battery pack accessory (bui lt-in to id controller) v600-a12 carrying belt accessory v600-a13 power supply 5 vdc from ac adapter permissible power supply voltage 5 vdc 5% current consumption 200 ma max. (see note 1.) insulation resistance 50 m ? min. (at 500 vdc) between cable terminals and case dielectric strength 1,000 vac, 50/60 hz for 1 mi n (1 ma max.) between cable terminals and case noise immunity power supply line: 1,200 vp-p i/o line: 800 vp-p vibration resistance destruction: 10 to 150 hz, 0.3-mm single amplitude, with 4 sweeps of 8 min each in 3 directions shock resistance destruction: 294 m/s 2 3 (approx. 20g) times each in 3 directions ambient temperature operating: -10 to 55 c with no icing; storage: -25 to 65 c with no icing ambient humidity 35% to 85% (with no condensation) operating conditions no corrosive gases enclosure ratings iec: ip63, jis: ipx3 (waterproof) see note 2. material case: abs resin; nameplate: pet resin cable length 2.5 m weight approx. 180 g (including the connector and cable)
electromagnetic coupling rfid system v600 11 idsc series note: refer to the applicable id controller o peration manual (cat. no. w250) for details. series idsc series model item idsc-c1dr-a idsc-c1dt-a host interface rs-232c possible number of r/w heads 1 power supply voltage 100 to 240 vac, 50/60 hz acceptable power supply voltage 85 to 264 vac power consumption 60 va max. insulation resistance 20 ? min. (at 500 vdc) between all power supply un it ac external terminals and ground terminals dielectric strength 2,300 vac, 50/60 hz for 1 min between po wer supply unit ac external terminals and ground terminals leakage current: 10 ma max. noise immunity 1,500-v (p-p) pulses of 100-ns to 1- s pulse width with a 1-ns rise time vibration resistance 10 to 57 hz, 0.075-mm amplitude, 57 to 150 hz, 9.8 m/s 2 acceleration for 80 min each in x, y, and z directions shock resistance 150 m/s 2 3 times each in x, y, and z directions ambient temperature 0 to 55 c ambient humidity 10% to 90% (with no condensation) operating conditions no corrosive gases storage temperature ? 20 to 75 c (excluding the battery pack) memory back-up the battery life is 5 years regardless of whether an rtc is provided. the period that data is retained after a power interruption depends on the ambient temperature. replace the battery within one week of the battery low indicator flashing. diagnostic functions checks for cpu errors, memory errors, power interruptions, and transmission errors ground ground to 100 ? or less. construction installed in panel weight approx. 1,500 g
12 electromagnetic coupling rfid system v600 transmission distance specificat ions for battery-less dcs note: 1. the transmission distance/transmiss ion time priority mode setting can be made usi ng the lower-level transmission mode setting s witch or memory switch only with a serial-int erface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmiss ion distance priority. 3. the specifications take fluctuations in ambient temperature and slight di fferences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p71 v600-h07 stationary read/write distance irrelevant 10 to 70 mm (max. axial offset 10 mm) these data carriers are for installa- tion on non-metallic surfaces only. data transmission will be impossi- ble if the dc is installed directly on a metal surface. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. moving 30 to 60 mm (max. axial offset 10 mm) v600-h11/-h11-r stationary read/write distance irrelevant 5 to 40 mm (max. axial offset 10 mm) moving 15 to 40 mm (max. axi- al offset 10 mm) v600-d23p72 v600-h07 stationary read/write distance irrelevant 10 to 50 mm (max. axial offset 10 mm) moving 30 to 40 mm (max. axial offset 10 mm) v600-h11/-h11-r stationary read/write distance irrelevant 5 to 30 mm (max. axial offset 10 mm) moving 15 to 30 mm (max. axial offset 10 mm) data carrier (resin, plastic, wood, etc.) non-metallic r/w head iron
electromagnetic coupling rfid system v600 13 note: 1. the transmission distance/transmissi on time priority mode setting can be made usin g the lower-level transmission mode setting s witch or memory switch only with a serial-int erface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight diff erences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p66n v600-h07 stationary read distance transmission distance priority 5 to 45 mm (max. axial offset 10 mm) data transmission will be impossi- ble if the dc is installed directly on a metal surface. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 5 to 35 mm (max. axial offset 10 mm) write distance irrelevant 5 to 35 mm (max. axial offset 10 mm) moving read distance transmission distance priority 25 to 40 mm (max. axial offset 10 mm) transmission time priority 25 to 30 mm (max. axial offset 10 mm) write distance irrelevant 25 to 30 mm (max. axial offset 10 mm) v600-h11/-h11-r stationary read distance transmission distance priority 5 to 30 mm (max. axial offset 10 mm) transmission time priority 5 to 25 mm (max. axial offset 10 mm) write distance irrelevant 5 to 25 mm (max. axial offset 10 mm) moving read distance transmission distance priority 15 to 25 mm (max. axial offset 10 mm) transmission time priority 15 to 20 mm (max. axial offset 10 mm) write distance irrelevant 15 to 20 mm (max. axial offset 10 mm) v600- d23p66sp v600-h07 stationary read distance transmission distance priority 5 to 40 mm (max. axial offset 10 mm) transmission time priority 5 to 30 mm (max. axial offset 10 mm) write distance irrelevant 5 to 30 mm (max. axial offset 10 mm) moving read distance transmission distance priority 20 to 40 mm (max. axial offset 10 mm) transmission time priority 20 to 30 mm (max. axial offset 10 mm) write distance irrelevant 20 to 30 mm (max. axial offset 10 mm) v600-h11/-h11-r stationary read distance transmission distance priority 5 to 25 mm (max. axial offset 10 mm) transmission time priority 5 to 20 mm (max. axial offset 10 mm) write distance irrelevant 5 to 20 mm (max. axial offset 10 mm) moving read distance transmission distance priority 10 to 25 mm (max. axial offset 10 mm) transmission time priority 10 to 20 mm (max. axial offset 10 mm) write distance irrelevant 10 to 20 mm (max. axial offset 10 mm) (resin, plastic, wood, etc.) non-metallic data carrier r/w head iron
14 electromagnetic coupling rfid system v600 note: 1. the transmission distance/transmiss ion time priority mode setting can be made usi ng the lower-level transmission mode setting s witch or memory switch only with a serial-int erface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmiss ion distance priority. 3. the specifications take fluctuations in ambient temperature and slight di fferences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p61 v600-h11/-h11-r stationary read distance transmission distance priority 2 to 19 mm (max. axial offset 10 mm) these data carriers can be in- stalled on metallic surfaces. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 2 to 16 mm (max. axial offset 10 mm) write distance irrelevant 2 to 16 mm (max. axial offset 10 mm) moving read distance transmission distance priority 12 to 19 mm (max. axial offset 10 mm) transmission time priority 13 to 16 mm (max. axial offset 10 mm) write distance irrelevant 12 to 16 mm (max. axial offset 10 mm) v600-h51 stationary read distance transmission distance priority 1 to 16 mm (max. axial offset 10 mm) transmission time priority 1 to 14 mm (max. axial offset 10 mm) write distance irrelevant 1 to 14 mm (max. axial offset 10 mm) moving read distance transmission distance priority 7 to 16 mm (max. axial offset 10 mm) transmission time priority 7 to 14 mm (max. axial offset 10 mm) write distance irrelevant 7 to 14 mm (max. axial offset 10 mm) data carrier iron iron (sc, ss) iron (sc, ss) data carrier r/w head iron v600-h5 r/w head
electromagnetic coupling rfid system v600 15 note: 1. the transmission distance/transmissi on time priority mode setting can be made usin g the lower-level transmission mode setting s witch or memory switch only with a serial-int erface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight diff erences between products into account. 4. this is the transmission di stance when using the v600-hs @ 1 and v600-ha51 combination. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p53 v600-hs51 (see note 4.) stationary read distance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) these data carriers are for flush mounting in metallic bases only. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-hs61 (see note 4.) stationary read distance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-h52 stationary read distance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-d23p54 v600-hs51 (see note 4.) stationary read distance transmission distance priority 0.5 to 6.0 mm (max. axial offset 2 mm) 0.5 to 6.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 5.0 mm (max. axial offset 2 mm) 0.5 to 5.5 mm (max. axial offset 1 mm) v600-hs61 (see note 4.) stationary read distance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) v600-h52 stationary read distance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write distance irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) iron (sc, ss) data carrier v600-hs61 r/w head iron iron(sc, ss) data carrier v600-hs51 r/w head iron iron ( sc, ss ) data carrier v600-h52 r/w head iron
16 electromagnetic coupling rfid system v600 note: 1. the transmission distance/transmiss ion time priority mode setting can be made usi ng the lower-level transmission mode setting s witch or memory switch only with a serial-int erface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmiss ion distance priority. 3. the specifications take fluctuations in ambient temperature and slight di fferences between products into account. 4. this is the transmission di stance when using the v600-hs @ 1 and v600-ha51 combination. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p55 v600-hs51 (see note 4.) stationary read distance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) these data carriers are for flush mounting in non-metallic bases only. the transmission distance decreas- es considerably when flush mount- ed in non-metallic bases. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) write distance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) v600-hs61 (see note 4.) stationary read distance transmission distance priority 0.5 to 7.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) write distance transmission distance priority 0.5 to 7.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) v600-h52 stationary read distance transmission distance priority 0.5 to 9.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 8.5 mm (max. axial offset 2 mm) write distance transmission distance priority 0.5 to 8.5 mm (max. axial offset 2 mm) transmission time priority 0.5 to 8.5 mm (max. axial offset 2 mm) data carrier v600-hs61 r/w head iron v600-hs51 r/w head iron v600-h52 r/w head iron (resin, plastic, wood, etc.) non-metallic data carrier (resin, plastic, wood, etc.) non-metallic data carrier (resin, plastic, wood, etc.) non-metallic
electromagnetic coupling rfid system v600 17 transmission distance specificati ons for built-in-battery dcs recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d8kr12 v600-h07 stationary flush- mounted in metal irrelevant 10 to 50 mm (max. axial offset 10 mm) the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and sram data carri- ers operation manual (cat. no. z127) for details. surface- mounted on metal 10 to 60 mm (max. axial offset 10 mm) moving flush- mounted in metal 25 to 50 mm (max. axial offset 10 mm) surface- mounted on metal 25 to 60 mm (max. axial offset 10 mm) v600-h11 stationary flush- mounted in metal irrelevant 5 to 40 mm (max. axial offset 10 mm) surface- mounted on metal 5 to 45 mm (max. axial offset 10 mm) moving flush- mounted in metal 25 to 40 mm (max. axial offset 10 mm) surface- mounted on metal 25 to 45 mm (max. axial offset 10 mm) v600-d8kr13 v600-h07 stationary flush- mounted in metal irrelevant 10 to 30 mm (max. axial offset 10 mm) surface- mounted on metal 10 to 35 mm (max. axial offset 10 mm) moving flush- mounted in metal 20 to 30 mm (max. axial offset 10 mm) surface- mounted on metal 20 to 35 mm (max. axial offset 10 mm) v600-h11 stationary flush- mounted in metal irrelevant 10 to 30 mm (max. axial offset 10 mm) surface- mounted on metal moving flush- mounted in metal 15 to 30 mm (max. axial offset 10 mm) surface- mounted on metal data carrie r surface-mounted on metal data carrier flush-mounted in metal r/w head all metal all metal all metal
18 electromagnetic coupling rfid system v600 note: 1. when data carriers are flush-mounted in metal, the read/ write distance will depend on the distance (x) between the side of the dc and the metal surface. 2. use the following method for fl ush mounting into a metallic base. combined with v600-h07 combined with v600-h11 v600-d8kr04 (unsealed) v600-h07 stationary flush- mounted in metal irrelevant see note1. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and sram data carri- ers operation manual (cat. no. z127) for details. surface- mounted on metal 10 to 100 mm (max. axial offset 10 mm) moving flush- mounted in metal see note1. surface- mounted on metal 50 to 100 mm (max. axial offset 10 mm) v600-h11 stationary flush- mounted in metal irrelevant see note1. surface- mounted on metal 10 to 65 mm (max. axial offset 10 mm) moving flush- mounted in metal see note1. surface- mounted on metal 30 to 65 mm (max. axial offset 10 mm) v600-d2kr16 v600-h11 stationary flush- mounted in metal irrelevant 2 to 15 mm (max. axial offset 10 mm) (see note 2.) surface- mounted on metal 2 to 15 mm (max. axial offset 10 mm) moving flush- mounted in metal 6 to 15 mm (max. axial offset 10 mm) see note 2.) surface- mounted on metal 10 to 15 mm (max. axial offset 10 mm) recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head flush-mounted mm mm 20 mm max. all metal refer to the v600 r/w heads and sram data carriers operation manual (cat. no. z127) for details. flush-mounted 10 mm min. 10 mm min. all metal transmiss ion distance (mm) 100 50 0 20406080 (axial offset: 0 mm) distance from metal surface ( ) (mm) r/w head data carrier (above 100) transmission distance (mm) 80 60 40 20 100 0 20406080 (axial offset: 0 m m r/w head data carrier distance from metal surface ( ) (m m (above 10
electromagnetic coupling rfid system v600 19 characteristic data (typical) transmission range note: the values shown in the following graphs ar e in millimeters. refer to the previous six pages for details on data carrier and r/ w head mount- ing conditions. battery-less compact dcs v600-d23p71 & v600-h07 v600-d23p72 & v600-h07 v600-d23p66n & v600-h07 v600-d23p66sp & v600-h07 v600-d23p61 & v600-h11 v600-d23p71 & v600-h11 v600-d23p72 & v600-h11 v600-d23p66n & v600-h11 v600-d23p66sp & v600-h11 v600-d23p61 & v600-h51 0 ? 20 ? 40 ? 60 ? 80 ? 100 ? 120 20 40 60 80 100 120 20 40 60 80 100 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 ? 120 20 40 60 80 100 120 20 40 60 80 100 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 y x x y 0 ? 10 ? 20 ? 30 ? 40 ? 50 10 20 30 50 40 10 20 30 40 y x x y 0 ?20 ?40 ?60 ?80 ?100 20 40 60 80 100 20 40 60 80 y x x y 0 ?20 ?40 ?60 ?80 20 40 60 80 20 40 60 y x x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 y x x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 10 ? 20 ? 30 ? 40 10 20 30 40 10 20 30 y x y x read range (in transmission distance priority mode) write range (in transmission distance or transmission time priority mode) read ran g e ( in transmission time p riorit y mode )
20 electromagnetic coupling rfid system v600 0 ? 5 ? 10 5 10 5 10 y y x x x 0 ? 5 ? 10 5 10 5 10 y x y x 0 ? 5 ? 10 5 10 5 10 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 15 10 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 15 10 y y x x 0 ? 5 ? 10 ? 15 5 15 10 5 15 10 x y y x 0 ? 5 ? 10 ? 15 5 10 15 5 10 15 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 10 15 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 10 15 x y y x v600-d23p53 & v600-hs51 +v600-ha51 v600-d23p53 & v600-hs61 +v600-ha51 v600-d23p53 & v600-h52 v600-d23p54 & v600-hs51 +v600-ha51 v600-d23p54 & v600-hs61 +v600-ha51 v600-d23p54 & v600-h52 v600-d23p55 & v600-hs51 +v600-ha51 v600-d23p55 & v600-hs61 +v600-ha51 v600-d23p55 & v600-h52 read range (in transmission distance priority mode) write range (in transmission distance or transmission time priority mode) read ran g e ( in transmission time p riorit y mode )
electromagnetic coupling rfid system v600 21 built-in-battery dcs v600-d8kr12 & v600-h07 v600-d8kr13 & v600-h07 v600-d8kr04 & v600-h07 v600-d8kr12 & v600-h11 v600-d8kr13 & v600-h11 v600-d8kr04 & v600-h11 replaceable-battery dcs v600-d2kr15 & v600-h11 0 ?20 ?40 ?60 ?80 ?100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 40 ? 80 ? 120 ? 160 40 80 120 160 40 80 120 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y read/write range (in transmission distance or transmission time priority mode)
22 electromagnetic coupling rfid system v600 transmission time ? the transmission time does not depend on the model of r/w head or data carrier, although transmission times differ between data carriers with and without batteries.  the turn around time (tat) is the total time required from the issu- ance of a command from the host device (for example, a host com- puter) until the reception of a response.  the lower-level communications time does not include the host communications; it is the ti me required for communications between the r/w head and data carrier. the lower-level communi- cations time is used in the equation for the dc speed. dc speed = (distance travelled in the transmission range)/ (lower-level communications time) transmission time with built-in-battery data carriers (reference) calculation (reference) n is the number of processing bytes. transmission time with battery-less data carriers (reference) calculation (reference) n is the number of processing bytes. lower-level communications mode se tting (distance/time priority) the lower-level communications mode setting is made with a dip swit ch or memory switch on the serial-interface controller (v600 -ca1a- @ / -ca2a- @ , v600-cd1d-v3, v600-cmid) or id sensor un it. (refer to the controller?s operation manual for more details on this setting.) with parallel-interface controllers (v600-ca8a-v2/ca9a-v2) the mode is fi xed to transmission distance priority. tat (turn around time) lower-level communication time command response rd001122 * rdh1 * lower-level communications time (ms) read t = 1.8 n + 48.4 write t = 4.2 n + 86.5 1,000 800 600 400 200 0 1 50 100 150 200 250 300 number of bytes lower-level communication time (ms) (auto) read (auto) write r/w lower-level communications time (ms) distance priority mode read t = 4.3 n + 64.6 write t = 8.7 n + 167.1 time priority mode read t = 1.8 n + 79.0 write t = 7.1 n + 180.4 2,500 2,000 1,500 1,000 500 0 50 100 150 200 250 300 number of bytes lower-level communication time (ms) (auto) read (auto) write transmission distance priority mode transmission time priority mode
electromagnetic coupling rfid system v600 23 battery life the data carrier has a built-in lithium battery. the following graphs show the relationship between the number of by tes per transmission, the number of transmissions per day, a nd the battery life. temperature and battery life v600-d2kr16 the battery life is two years at 25 c regardless of the relationship between the number of bytes read/written and the number of transmissions. examples showing relationship between battery life and temperature the following table shows the standard values. note: if the battery is stored at 70 c and is not installed, the battery life is calculated as follows: 2 (years) (1 - 0.32) = 1.36 years if the battery is stored at 25 c after one year?s storage, the bat- tery life will be approximately 1 year and 4 months. (the battery life will be shortened if the battery is used at temperatures close to 0 c or 50 c.) the values in the above graph are based on the battery being instal led (i.e., the insulation sheet is removed). if the battery is not installed, the values shown in the above table will apply. precautions correct use data carrier batteries built-in-battery data carriers !caution do not disassemble, deform by applying pressure, heat at temper- atures exceeding 100 c, or burn. doing so may cause the built-in lithium batteries to combust or explode. replaceable-battery data carriers !caution never short-circuit the positive and negative terminals of the bat- teries, charge the batteries, disa ssemble them, deform them, or throw them into a fire. doing so may cause the batteries to ex- plode, combust, or leak liquid. 1,000 500 300 100 50 30 10 5 3 1 0 40 80 120 160 200 240 280 1,000 500 300 100 50 30 10 5 3 1 0 40 80 120 160 200 240 280 1,000 500 300 100 50 30 10 5 3 1 0 40 80 120 160 200 240 280 bytes per transmission transmission s/day (x100) 5 yrs 8 yrs bytes per transmission 5 yrs 8 yrs bytes per transmission 5 yrs 8 yrs v600-d8kr12 (typical example) v600-d8kr13 (typical example) v600-d8kr04 (typical example) transmission s/day (x100) transmission s/day (x100) 2.5 2 1.5 1 0.5 01020304050 ambient temperature ( ? c) battery life (years) temperature battery consumption rate in one year 20 c1% 30 c2% 40 c4% 50 c8% 60 c 16% 70 c 32%
24 electromagnetic coupling rfid system v600 mutual interference mutual interference between r/w heads when using more than one set of r/w heads, mutual interference between the heads can be avoided by mounting the heads at the sp ecified distance as shown below. v600-h07  facing rd/wt command: 650 mm min. auto command: 900 mm min.  side-by-side rd/wt command: 550 mm min. auto command: 1,200 mm min. v600-h11  facing rd/wt command: 200 mm min. auto command: 200 min.  side-by-side rd/wt command: 200 min. auto command: 200 mm min. v600-hs61  facing: 80 mm min.  side-by-side: 80 mm min. note: if the two r/w heads are not transmitting simultaneously (i.e., independent read/write), mutual in terference will not occur. th erefore, the restriction on the distance between the heads will not be applicable. the commands will be received by the r/w heads and transmission will oscillate between them. 650 mm min. ( 900 mm min. ) 550 mm min. (1,200 mm min.) 200 mm min. 200 mm min. 120 mm min. 80 mm min. 80 mm min. v600-hs51 v600-hs51 v600-h51  facing: 120 mm min. v600-h52  facing: 80 mm min.  side-by-side: 80 mm min. v600-hs51  facing: 80 mm min.  side-by-side: 80 mm min. 100 mm min. 80 mm min. 80 mm min. v600-hs51 v600-hs51  side-by-side: 100 mm min. 80 mm min. v600 -hs61 v600 -hs61 80 mm min.
electromagnetic coupling rfid system v600 25 mutual interference between proximity sensors the v600-series units use electromagnetic coupling (frequency: 530 khz). when a v600 unit is wired close to r/w heads, proximit y switches, and sensors that have an oscillating frequency between 400 and 600 khz, the proximity sensor may malfunction, so be sure to ins tall the units according to the distance restrictions specified in the followin g diagrams. make sure to thoroughly test that the mounting posi tions and the fixed positions of the sensors ar e correct before putting them into actual operation. v600-h07  vertical: 400 mm min.  facing: 300 mm min. v600-h11  vertical: 100 mm min.  facing: 100 mm min. 400 mm min. 400 mm min. proximity sensor proximity sensor v600-h07 300 mm min. proximity sensor v600-h0 7 100 mm min. 100 mm min. proximity sensor proximity sensor v600-h11 100 mm min. proximity sensor v600-h11 100 mm min. 200 mm min. 150 mm min. v600-h51/52 proximity sensor proximity sensor proximity sensor 100 mm min. 150 mm min. v600-hs51 proximity sensor proximity sensor proximity sensor 100 mm min. 100 mm min. 100 mm min. v600-hs61 v600-hs61 proximity sensor proximity sensor proximity sensor v600-h51/h52 v600-hs51 v600-hs61
26 electromagnetic coupling rfid system v600 mutual interference between data carriers when more than one data carrier is used, mutual interference between the dcs can be avoided by making sure that they are mounte d apart at the distances specified below. (reading/writing) v600-d23p53 r/w head: v600-h52, v500-hs51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p55 r/w head: v600-h52, v600-hs51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p66n r/w head: v600-h11 r/w head: v600-h07 v600-d23p54 r/w head: v600-h52, v600-hs 51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p61 r/w head: v600-h11/-h51 v600-d23p66sp r/w head: v600-h11 r/w head: 600-h07 v600-d23p72 v600-d23p66sp r/w head: v600-h07 40 mm min. 50 mm min. 140 mm min. 160 mm min. 45 mm min. 90 mm min. 140 mm min. 160 mm min. 150 mm min. 120 mm min. 170 mm min. 140 mm min. 210 mm min. 180 mm min. r/w head: v600-h51 r/w head: v600-h11 r/w head: v600-h07 290 mm min. 210 mm min.
electromagnetic coupling rfid system v600 27 v600-d8kr12 r/w head: v600-h11 r/w head: v600-h07 v600-d8kr13 r/w head: v600-h11 r/w head: v600-h07 v600-d8kr04 r/w head: v600-h11 r/w head: v600-h07 v600-d2kr16 r/w head: v600-h11 140 mm min. 140 mm min. 160 mm min. 160 mm min. 160 mm min. 160 mm min. 180 mm min. 160 mm min. 180 mm min. 180 mm min. 220 mm min. 150 mm min. 90 mm min.
28 electromagnetic coupling rfid system v600 dimensions note: all units are in millimeters unless otherwise indicated. data carriers built-in-battery dcs v600-d8kr12 v600-d8kr04 v600-d8kr13 replaceable-battery dcs v600-d2kr16 battery-less dcs v600-d23p66n v600-d23p66sp 40 30 0.2 10 65 55 0.2 5 27 10 two, 4.5-dia. mounting holes 15 8 case: abs resin filler: epoxy resin 54 20 44 0.2 10 86 31 four, 4.5-dia. mounting holes 5 5 76 0.2 case: abs resin filler: epoxy resin 86 27 two, 4.5-dia. mounting holes 10 54 440.2 10.3 5 5 760.2 10 case: abs resin filler: epoxy resin 65 4-r1.5 40 5 r0.5 case: abs resin 5 0 ? 0.1 6 0 ? 0.2 5 0 ? 0.1 24 2.2 6 36 30 0.1 24 r0.2 8 0 ? 0.1 dia. 2-r1.0 r0.3 12 0 ? 0.2 dia. r0.2 8 0 ? 0.1 dia. two, 3.5-dia. mounting holes v600-d23p53 v600-d23p54 v600-d23p55 v600-d23p61 case: abs resin filler: epoxy resin case: abs resin filler: epoxy resin case: pps resin filler: epoxy resin case: abs resin filler: epoxy resin 4-r4 32 34 25 0.2 4-r3 32 34 25 0.2 two, 6-dia. 3.5 0.1 two, 3.5-dia. 25 0.2 25 0.2 2-m3 case: pps resin mounting hole dimensions 2-m5 4-r6 6.5 2.5 max. 34 36.5 34 80 0.2 95 1.3 80 0.2 mounting hole dimensions coating: pfa resin two, 5.5-dia. mounting holes
electromagnetic coupling rfid system v600 29 v600-d23p71 v600-d23p72 r/w heads v600-h07 v600-h11 v600-h51 v600-hs51 (sensor section) 54 1.5 86 4-r2 case: glass epoxy resin coating: polyurethane resin 50 4-r2 34 1.5 case: glass epoxy resin coating: polyurethane resin 50 5 5 100 90 0.2 four, 4.5-dia. mounting holes 100 90 0.2 50 14 power indicator (green) transmission indicators (orange) 10 10 25 43 connector 14.7 dia. bushing vinyl-insulated round cord (6-mm dia.) 30 20 11 case: abs resin filler: epoxy resin cable: pvc (oil-resistant) 23 11 5 power (green)/transmission (orange) indicators 5 4-r1 40 28 2-r5 two, 4.5-dia. mounting holes 10 bushing 14.7 dia. 43 vinyl-insulated round cord (6-mm dia.) connector 27 53 6 20 18 13 5 accessories: two brackets for rear panel mounting case: abs resin filler: epoxy resin cable: pvc (oil-resistant) 19.8 dia. 7 62.5 m22x1 2 lock washers 2 lock nuts power (green)/transmission (orange) indicators vinyl-insulated round cord (6-mm dia.) connector (66) (72) 80 43 14.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant) 33 35 49.5 7 m12x1 2 lock washers 2 lock nuts vinyl-insulated round cord (4-mm dia.) connector 9.6 dia. 13.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant)
30 electromagnetic coupling rfid system v600 v600-h52 v600-hs61 (sensor section) v600-ha51 (amplifier section) 12 dia. 12 67.5 m22x1 2 lock washers 2 lock nuts power (green)/transmission (orange) indicators vinyl-insulated round cord (6-mm dia.) connector (71) (77) 85 43 14.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant) 30.5 18 4.5 8.5 12 0.1 49.5 18 10 13.7 dia. detection surface connector vinyl-insulated round cord (4-mm dia.) 6.5 two, 3.5x5 mounting holes case: abs resin filler: epoxy resin cable: pvc (oil-resistant) 22.6 36.5 23.5 8 6.1 vinyl-insulated round cord 6-mm dia (7/0.18-mm dia.), 8-conductor cable connector 14.7 dia. 35.6 13.2 two, 4.5-dia. mounting holes 51.3 0.2 4 13.7 dia. 22 51.7 61.8 5.9 5 12.8 dia. (10,000) 43 power indicator (green) connector operating indicator (orange) case: abs resin filler: epoxy resin cable: pvc (oil-resistant)
electromagnetic coupling rfid system v600 31 id controllers idsc-c1d @ -a (stand-alone) 9.3 35.3 100 200 190 0.3 90 0.3 100 80.6 120.6 22.6 open 5.5 53 81 92 115 80 50 17.5 18 68 76 78 92 102 21.5 9 6 5 57.4 86.3 95 107 16.5 105 45.5 270 80 38 four, 4.3-dia. mounting holes v600-ca @ a- @ (multi-purpose) v600-cd1d-v3 (compact) two, 4.5-dia. four, 3.5-dia. r/w head connector v600-cm1d (board-mounted) v600-p01 monitor unit (for use with v600-ca @ a- @ ) v600-cb-us handheld id controller 110 219 107
32 electromagnetic coupling rfid system v600 accessories v600-ch1d handheld reader/writer holder v600-a81 for v600-d2kr16 data carriers v600-a84 for v600-d23p71/-d23p72 data carriers attachment v600-a86 for v600-d23p66n data carriers 10.5 dia. connector 34.5 19020 32.2 24.99 44.9 2500 +50 0 106.5 10.5 23 sensing surface connector note: requires eiaj class 2 plug (4.0 x 1.7 mm) from power source vinyl-insulated flat cable, 2 2 mm dia. (12/0.18 mm dia.), 2-core, standard length: 0.19 m 4 5 65 2 3 3 4 9 5 . 5 2 5 operation indicator operation indicator a c tiv a t e s wit ch r ese t s wit ch 11 9 3.5 2-r2.5 20 42 24 0.1 68 40 0.1 (four, 3.5-dia.) (four, 5.5-dia.) 8-r0.5 case: abs resin 2.1 95.6 2.1 4-r3 24.4 99.8 0.5 42.5 2.1 63.6 2.1 8.5 5 67.8 0.5 use m3 countersunk screws in the two 3.2-dia. mounting holes or apply ultrasonic welding. 25 0.2 25 0.2 25 0.2 25 0.2 15 34 37 15 34 37 16 4 10 3.5 two, 4-dia. 4-r5.5 2-m3 material: pps resin mounting hole dimensions all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527.
electromagnetic coupling rfid system v600 33 terms and conditions warranty, limitations of liability warranty omron?s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability or fitness for particular purpose of the products. any buyer or user acknowledges that it alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsi- ble for special, indirect or consequential damages, loss of profits or commercial loss in any way con- nected with the products, whether such claim is based on contract, warranty, negligence or strict liability. in no event shall responsibility of omron for any act exceed the indi- vidual price of the product on which liability is asserted. in no event shall omron be responsible for war- ranty, repair or other claims regarding the prod- ucts unless omron?s analysis confirms that the products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for confor- mity with any standards, codes or regulations which apply to the combination of the product in the customer's application or use of the product. at the customer's request, omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the product. this information by itself is not sufficient for a complete determination of the suitability of the product in combi- nation with the end product, machine, system, or other application or use. the following are some examples of applications for which particular attention must be given. this is not intended to be an exhaustive list of all possible uses of this product, nor is it intended to imply that the uses listed may be suitable for this product:  outdoor use, uses involving pot ential chemical contamination or electrical interference, or conditi ons or uses not described in this catalog.  nuclear energy control systems, combustion systems, railroad sys- tems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.  systems, machines and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to this product. never use the product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. programmable products omron shall not be responsible for the user?s programming of a programmable product, or any con- sequence thereof. disclaimers performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?s test conditions, and the user must correlate it to actual application requirements. actual performance is subject to the omron war- ranty and limitations of liability. change in specifications product specifications and accesso- ries may be changed at any time based on improvements and other reasons. it is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. however, some s pecifications of the product may be changed without any notice. when in doubt, special part numbers may be assigned to fix or establish key specifications for your appli- cation. please consult with your omron representative at any time to confirm actual specific ations of purchased product. errors and omissions the information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for cler ical, typographical or proofreading errors, or omissions. omron on-line global - http://www.omron.com usa - http://www.omron.com/oei canada - http://www.omron.ca all dimensions shown are in millimeters. to convert millimeters into inches, divide by 25.4 cat. no. gc rfid 4 printed in usa omron canada, inc. 885 milner avenue toronto, ontario m1b 5v8 416-286-6465 omron electr onics llc one commerce drive schaumburg, il 60173 847-843-7900 for us technical support or other inquiries: 800-556-6766 5/03 specifications subject to change without notice complete terms and conditions for product purchase and use are on omron?s website at www .omron.com /oei ? under the ?about us? tab, in the legal matters section.


▲Up To Search▲   

 
Price & Availability of XW2Z-500P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X